ANALISIS KARAKTERISTIK MINYAK TRANSFORMATOR MENGGUNAKAN PENGUJIAN DISSOLVED GAS ANALYSIS (DGA) PADA IBT 1 GARDU INDUK
DOI:
https://doi.org/10.54757/fs.v12i1.142Keywords:
Transformer, DGA, TDCG.Abstract
Electrical energy is an important factor to support people's lives. Electrical energy from the generator is channeled through a transmission line to the substation. Transformer (transformer) is a very important equipment in the electric power system. Inside there is oil which functions as an insulating medium and also as a cooling medium. This electrical and thermal load can cause dissolved gases in the transformer oil. This DGA (Dissolved Gas Analysis) test aims to determine the content of dissolved gases in transformer oil and then to analyze using three fault indication methods Total Dissolved Combustible Gas (TDCG) Method, Roger Ratio, and Duval Triangle. Results The analysis uses these three methods to determine corrective actions according to the condition of the transformer oil. Corrective action to return the dissolved gases in the transformer oil back to normal. Transformer oil filtering aims to remove or reduce potentially damaging gases from the transformer oil content. On December 29, 2020 the transformer experienced an increase in the content of flammable hydrogen gas and acetylene gas, the TDCG value was 1520 ppm and after corrective action the dissolved gas content decreased to 481 ppm, so that the condition of the transformer oil returned to normal.
References
Agus Siswanto, R.A., Erfan Subyanta, analisis kinerja pms rel 2 bay trafo 6 menggunakan thermovision methode di gardu induk sunyaragi. Jurnal Ilmiah Foristek 2021. 11: p. 47-43.
Siswanto, A., et al., Stability improvement of wind turbine penetrated using power system stabilizer (PSS) on South Sulawesi transmission system. AIP Conference Proceedings, 2018. 1941 (1): p. 020036.
Yuli Asmi Rahman, A.S., and irwan Mahmudi, Stability Issues in Presence Variable Distributed Generation Into Radial Distribution Network International Conference on Industrial Electrical and Electronics (ICIEE) 2018.
Agus Siswanto, I.C.G., Sri Mawar Said, Ansar Suyuti, Stability Improvement by Reducing Voltage Fluctuation using SVC in Penetration Wind Power System EPI International Conference on Science and Engineering, 2019.
Siswanto, A., Steady State Stability Limit Assessment when Wind Turbine Penetrated to the Systems using REI Approach. Vol. 1. 2019. 53-57
Institute of Electrical and Electronics Engineers. 2009. Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers. New York USA : IEEE Power & Energy Society
Institute of Electrical and Electronics Engineers. 2006. Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers. New York USA : IEEE Power & Energy Society
Feriyanto,Y.E. 2008. Analisa Dissollved Gas Analysis (DGA) di Minyak Trafo. Surabaya. www.caesarvery.com
PT PLN (Persero). 2014. Himpunan Buku Pedoman Pemeliharaan Peralatan Primer Gardu Induk. http://academia. edu/37218274/ buku_pedoman_ Trafo_ Tenaga_final
Prayoga, Aditya. 2010. Transformator. Depok. Teknik Tenaga Listrik. Departemen Teknik Elektro. Fakultas Teknik. Universitas Indonesia.
Rahmatullah, Arif K. 2008. Analisis Indikasi Kegagalan Transformator dengan metode disolled gas analys. FT UNDIP. Semarang
“Perawatan Trafo Pembangkit” PT PLN (Persro). 2014. Himpunan Buku Pedoman Pemeliharaan Peralatan Primer Gardu Induk.https://www.academia.edu/37218274/Buku_Pedoman_Trafo_Tenaga_Final
“Pengujian Transformator” Saputra, Dimas Abimanyu. 2018. Analisis pengujian Transformator Daya MT24 150kV/33kV 90MVA di PT Vale Indonesia, Sorowako-Sulawesi Selatan. http://eprints.umm.ac. id/37361/4/jiptummpp-gdl-dimasabima-51 515-3-babii.pdf
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Agus Siswanto, Abdul Rohman
This work is licensed under a Creative Commons Attribution 4.0 International License.