ANALISIS KARAKTERISTIK MINYAK TERHADAP TEGANGAN TEMBUS TIGA JENIS MINYAK SEBAGAI ALTERNATIF MINYAK ISOLASI TRANSFORMATOR

Authors

  • Ika Novia Aggraini
  • Hoklan Roianri Rifki Rinaldi Situngkir
  • Yuli Rodiah
  • Reza Satria Rinaldi
  • Muhmammad Arfan

DOI:

https://doi.org/10.54757/fs.v15i1.754

Keywords:

Breakdown voltage, insulating liquid, vegetable-based oil, viscosity, water content.

Abstract

This research seeks to assess the influence of viscosity and moisture content on the breakdown voltage of canola oil, corn oil, and sunflower seed oil, as well as to evaluate the quality and properties of these oils as potential alternative liquid insulations for transformers. Transformer liquid insulation specifications according to SPLN 50-1982 and IEC 60247:1991 standards include a breakdown voltage of 30 kV/2.5 mm, a maximum moisture content of 30 ppm or 0.003%, and a kinematic viscosity of 40 cSt at 20°C. During the assessment of moisture content and viscosity, two oil conditions are examined: fresh oil and old oil after the breakdown voltage test. The test data indicates that moisture content and viscosity influence breakdown voltage. Specifically, canola oil, with a moisture content of 0.17% and a viscosity of 28 cSt, exhibits a breakdown voltage of 20.5 kV/2.5 mm; corn oil, with a moisture content of 0.11% and a viscosity of 27 cSt, demonstrates a breakdown voltage of 25.3 kV/2.5 mm; sunflower seed oil, with a moisture content of 0.12% and a viscosity of 26 cSt, shows a breakdown voltage of 21.5 kV/2.5 mm. Nevertheless, the test findings indicate that the breakdown voltage fails to comply with the transformer insulating oil requirement.

References

H. Panjavi, I. Tanjung, dan F. Mulia. 2018. "Karakteristik Tegangan Tembus AC Campuran Minyak Jarak dan Minyak Mineral Sebagai Pertimbangan Alternatif Isolasi Cair" . Pekanbaru: Universitas Riau.

S. Samsulrizal, A. Makkulau, dan S. A. Zahra. 2022. "Studi Pengujian Karakteristik Minyak Nabati Terhadap Tegangan Tembus Sebagai Alternatif Pengganti Minyak Trafo" . Jakarta Barat: Institut Teknologi PLN. [3] C. Widyastuti dan R. A. Wisnu Lajuwijaya. 2019. "Analisis Tegangan Tembus Minyak Transformator di PT. PLN (Persero) Bogor" . Bogor: Sekolah Tinggi Teknik PLN.

F. R. A. Bulaiti. 2021. "Analisis Kekuatan Dielektrik Minyak Campuran Metil Ester

Bunga Matahari Sebagai Isolasi Cair pada Transformator" . Medan: Universitas Sumatera Utara.

E. Seltiyandani, Widjonarko, dan Sulprihadi Prasetyonoo. 2021. "Uji Karakteristik Bio Minyak Trafo Berbahan Dasar Minyak Kelapa Dengan Penambahan Zat Aditif Butilatet Hidroksitoluen (BHT) Sebagai Alternatif Isolasi Cair Transformator Daya 150 KVA" . Jember: Universitas Jember.

R. Kamelia Putra. 2017. "Karakteristik Tegangan Tembus Arus Bolak Balik Pada Minyak Jarak Pagar (Jatropha Curcas) Sebagai Alternatif Isolasi Cair" . Pekanbaru: Universitas Riau.

S. Ferolim. 2022. "Karakteristik Tegangan Tembus Pada Canola Oil Dengan Penambahan Nanopartikel Aluminium Sebagai Alternatif Pengganti Minyak Transformator" . Palembang: Universitas Sriwijaya.

H. T. Kurrahman, S. Abdulah. 2016. "Studi Tegangan Tembus Minyak Kelapa Sebagai Alternatif Pengganti Isolasi Transformator Daya" . Jakarta Barat: Universitas Trisakti.