ANALISIS STARTING MOTOR INDUKSI PADA BALL MILL PLANT DENGAN LIQUID RESISTANCE STARTER DI PT CITRA PALU MINERALS

Authors

  • Muhammad Bintang Alfito
  • Ahmad Antares Adam
  • Martdiansyah Martdiansyah
  • Baso Mukhlis
  • Yulius Salu Pirade
  • Maryantho Masarrang

DOI:

https://doi.org/10.54757/fs.v15i2.839

Keywords:

Induction Motor, Liquid Resistance Starter, Direct On Line, Wye-Delta, Starting Performance, Ball Mill Plant

Abstract

The 3700 kW induction motor at the Ball Mill Plant at PT Citra Palu Minerals requires an effective starting method to prevent current surges and voltage drops during initial operation. This study aims to analyze the starting performance of induction motors using three starting methods, namely Liquid Resistance Starter (LRS), Direct On Line (DOL), and Wye-Delta. The analysis is carried out by mathematical calculations through the induction motor equivalent circuit to obtain the starting current, starting torque, starting power and starting voltage values of each starting method. The calculation results show that the LRS method produces a starting current of 421.47 A, a starting torque of 42,259.84 Nm, a starting power of 4,423.19 kW and a starting voltage of 6,374.40 V. Compared to DOL and Wye Delta, the LRS method provides better performance in terms of limiting current and maintaining voltage stability, and is able to produce higher torque and power. The calculation of the LRS method also shows conformity with the actual data in the field, so that the model used can be used as a technical reference. Based on the analysis results, the LRS method is considered the most suitable for starting high power induction motors in heavy-load applications such as Ball Mill Plant.

References

Aqute Prima. (2022). Arus Start Pada Motor Induksi[Videorecording].www.youtube.com.

Aulia, S. A., Soedjarwanto, N., & Safaruddin,

S. (2023). Analisis Starting Main Motor Coal Mill Dengan Liquid Resistance Starter Di Pt Semen Baturaja Tbk. Jurnal Informatika Dan Teknik Elektro Terapan, 11(3s1).

Cik, A., Mardiah, & Guskarnali. (2020). Kajian Produksi Ball Mill Dalam Menentukan Efektivitas Penggerusan Bijih Timah Primer Di CV Persada Tambang Intitama TK 4.218 Paku Kabupaten Bangka Selatan. Jurnal Mineral, 5(2), 1–6.

GAMAK. (2023). Medium Voltage Electric Motors. GAMAK Power To Energize Life.

Herwin. (2017). Analisis Perbandingan Starting Motor Induksi 3-Fasa Menggunakan Liquid Rotor Starter (LRS) dan Oil Rotor Starter (ORS) 101 (Studi Kasus di Pabrik Indarung V PT Semen Padang) [Skripsi Sarjana]. Universitas Andalas.

Kurniawan, A. R. I., & Yandri, W. (2020). Operasi Motor Listrik Dengan Sistem Kendali Star Delta Menggunakan Plc Zelio Sr3B101Fu. Ensiklopedia of Journal, 2(5), 1–

Meidiasha, D., Rifan, M., & Subekti, M. (2020). Alat Pengukur Getaran, Suara Dan Suhu Motor Induksi Tiga Fasa Sebagai Indikasi Kerusakan Motor Induksi Berbasis Arduino. Journal of Electrical Vocational Education and Technology, 5(1), 27–31.

Nizar, R., & Baihaqi, I. (2020). Studi Inspeksi Kelayakan Instalasi Dan Instrumen Tenaga Listrik. Sinusoida, 22(2), 21–33.

Downloads

Published

2025-11-30

How to Cite

[1]
M. B. Alfito, A. A. Adam, M. Martdiansyah, B. . Mukhlis, Y. S. Pirade, and M. Masarrang, “ANALISIS STARTING MOTOR INDUKSI PADA BALL MILL PLANT DENGAN LIQUID RESISTANCE STARTER DI PT CITRA PALU MINERALS”, Fs, vol. 15, no. 2, Nov. 2025.

Issue

Section

Articles

Most read articles by the same author(s)

1 2 3 > >>